        Professional Design China Primary Current Injection Heavy Duty Temperature Rise Test Panel Upto 4000A

        Adopting domestic leading inverter and control technology, green and environmental protection, energy saving design; No power consumption if not in emergency power supply; no noise pollution using smart cooling fan;
        Fume and dust free, using the latest fire prevention corrosion resistant material with professional fire prevention safety design to keep away from fire hazards.
        Using intelligent module, CPU control, pure sine wave output, strong load adaptability, suitable for inductive load and mixed load, good balance and impact resistance, stable performance, high reliability and long service life;
        Easy to maintain, can be monitored by computer, automaitic switch between external power grid and the battery, unattended operation, mutual switch time ≤3S; high –speed switchover type: ≤2ms (suitable for places with High Pressure Sodium Lamp)
        Smart battery management: can adjust number of batteries, battery voltage (upper and lower limits), set the battery failure recovery voltage (upper and lower limits), set up regular battery testing, the battery voltage, battery failure alarm, etc.

        Read More>>


        Product Detail

        Product Tags

        Overview

        JC - D series EPS for of fire emergency lighting provides emergency power supply for all kinds of AC/DC evacuation indicator lamps, high-power lighting (high pressure sodium lamp, metal halide lamp, other lamps and lanterns of high brightness), fire control broadcast, intercom system, security monitoring system and automatic spray system to maintain system normal operation in case of no city power.The centralized power supply is suitable for all kinds of AC/DC hybrid complex fire electrical applications.
        Feature
        1、Adopting domestic leading inverter and control technology, green and environmental protection, energy saving design; No power consumption if not in emergency power supply; no noise pollution using smart cooling fan;
        2、Fume and dust free, using the latest fire prevention corrosion resistant material with professional fire prevention safety design to keep away from fire hazards.
        3、Using intelligent module, CPU control, pure sine wave output, strong load adaptability, suitable for inductive load and mixed load, good balance and impact resistance, stable performance, high reliability and long service life;
        4、Easy to maintain, can be monitored by computer, automaitic switch between external power grid and the battery, unattended operation, mutual switch time ≤3S; high –speed switchover type: ≤2ms (suitable for places with High Pressure Sodium Lamp)
        5、Smart battery management: can adjust number of batteries, battery voltage (upper and lower limits), set the battery failure recovery voltage (upper and lower limits), set up regular battery testing, the battery voltage, battery failure alarm, etc.

        Technical Index

        Centrally connected power source

        J C- D -1KVA-2KVA

        J C- D -3KVA-10KVA

        Input

        voltage

        Single phase 220V(1±25%)

        frequency

        50Hz ((1±5%))

        Output

        voltage

        Normal: synchronous with city power; Emergency: 220 VAC ((1±3%))

        frequency

        Normal: synchronous with city power; Emergency: 50Hz ((1±0.5%))

        waveform

        Pure sine wave

        Battery

        type

        96VDC Sealed maintenance free

        nominal voltage

        96VDC

        96VDC-216VDC (492VDC for high-speed switchover type)

        charge time

        <24H

        Switch time

        <0.25s

        Emergency power supply time

        Normal: 90min (can be customized)

        Load ability

        120% 60s; 150% 5s

        Protection function

        lack voltage, over current, short circuit

        Noise (1M)

        When city power normal: no noise? emergency:?<55db

        Working environment

        humidity

        10%-90%

        temperature

        -10?℃-40?℃

        altitude

        <2000m

        Adaptive load

        Adapt to all lighting loads

        Output circuit (standard type)

        4

        Outer size

        ?201707030313207997 ?201707030313265810

      2. Previous:
      3. Next:

        1. <code id="62nq2"><nobr id="62nq2"><sub id="62nq2"></sub></nobr></code>

          <tr id="62nq2"></tr>
        2. <strike id="62nq2"></strike>
          <strike id="62nq2"><menu id="62nq2"><listing id="62nq2"></listing></menu></strike>

            <menu id="62nq2"><noframes id="62nq2"><u id="62nq2"></u></noframes></menu>
          1. <th id="62nq2"><option id="62nq2"></option></th>
            {关键词}